Duration
5 days
Course Description
With few exceptions, enterprises today rely on IT for the delivery of business-critical services - often directly to the end consumer. It is therefore vital that the mission critical data Centre is designed, maintained and operated with hi-availability and efficiency in mind. Fact is however that most data Centre’s do not meet the full availability, capacity, safety or efficiency requirements often demanded.
CDCS® will further increase attendees to a level being a compatible sparring partner with suppliers and they will be able to verify offers provided by vendors for correctness, eeffectiveness and efficiency. CDCS® is a must have certification for professional data Centre managers and Personnel. CDCS® is a pre-requisite for individuals wishing to achieve the CDCE® status.
Certified Data Centre Courses
There are three levels of certification for Mission Critical Site Facilities courses:-CDCE®: Certified Data Centre Expert-CDCS®: Certified Data Centre Specialist-CDCP®: Certified Data Centre Professional
For Data Centre Facility Operations, refer to our CDFOM®: Certified Data Centre Facilities Operations Manager course.
Audience
The primary audience for this course is an IT, facilities or Data Centre Operations professional working in and around the data Centre and having the responsibility to achieve and improve hi-availability and manageability of the Data Centre.
Prerequisites
Participants must hold a valid CDCP® certificate in order to be able to register for the CDCS® class.
Delivery Structure
EPI courses are lectured by certified trainers. CDCS® is an instructor-led course that uses a combination of presentation lectures and question and answer sessions, to discuss attendees’ specific needs and issues experienced in their own environment. Attendees are able to tap on the trainer’s extensive experience to solve practical problems in their current environment, adding tremendous value.
At Course Completion
After completing this course, you will be able to:
- Understand the design life cycle of data centres and the stages involved
- Discuss in great level of detail requirements with vendors, suppliers and contractors to ensure they meet the customers’ requirement
- Verify on the technical level design plans, quotes and offers proposed by vendors/contractors
- Understand Tier-levels for both the data centre design/setup as well as maintenance tier levels
- Understand the various building considerations such as bullet proofing, mitigation of seismic activity, fire ratings and thermal stability
- Understand how to build up a raisedfloor meeting requirements to avoid misalignment, level differences and leakage
- Understand how to read a Single Line Electrical Diagram being able to identify the most common design issues made
- Choose the correct UPS and parallel configuration; learn how to avoid classic mistakes when installing systems in parallel
- Understand how to calculate battery banks enabling you to double check offered configurations to ensure it meets the customers’ requirements
- Understand what distance to keep to avoid EMF issues for human safety and equipment disturbances
- Understand the fundamental cooling setup, CFM, Delta-T and other important factors
- Understand contamination factors and limitations
- Understand full details of re suppression options, how to calculate gas content and verify installations
- Understand how to measure data centre energy efficiency and how to improve it
Certification & Accreditation
Attendees who successfully pass the exam will receive the official ‘Certified Data Centre Specialist’ certificate. Certification is valid for a three years period after which the student needs to re-certify.
EXIN is a global, independent and not-for-profit examination provider. EXIN's mission is to improve the quality of the IT and Data Centre sectors, the proficiency of IT and Data Centre professionals and the IT users, by means of independent testing and certification. EXIN offers candidates the opportunity to take examinations at a time and place of their choice. Every day, EXIN examinations are taken in more than 125 countries on six continents, and in more than 15 languages.
The Professional Engineers Board Singapore (PEB) is a statutory board in the Ministry of National Development. PEB was established since 1971 under the Professional Engineers Act. PEB’s Mission is to safeguard life, property, and welfare of the public by setting and maintaining high standards for registering professional engineers, and by regulating and advancing the practice of professional engineering.
In the USA (United States of America), the course is accredited and administered by ICOR. ICOR is a not-for-profit education and credentialing organization that provides professional development, certification, thought-leadership, and the latest in research and industry trends in the area of organizational resilience.
Course Outline
Data Centre Design / Life Cycle Overview
- Overview of the phases of a data centre life cycle
- Planning, re-alignment and continuous improvement
Tier Levels
- History of ‘tier level’ definitions
- Tier level definitions, categories and measure points
- Redundancy options
- Tiered Infrastructure Maintenance Standards (TIMS)
Building Considerations & Standards
- Floor loading requirements
- Fire rating for walls and glass
- Blast protection
- Bullet proofing
- Forced entry protection
Advanced Raised Floor & Suspended Ceiling
- Raised floor installation guidelines to ensure contractors install a proper closed and leveled raised access floor
- Choosing the right tiles and their locations
- Seismic mitigating floor constructions
- Choosing the correct suspended ceiling
Advanced Power
- Power infrastructure layout;
- Formulas which you should know for the data centre
- Single Line Electrical diagrams; how to read to ensure key components are present for protection
- Over current protection devices (MCB/MCCB/VCB/ACB/Fuses) definitions and what to use where
- Earth Leakage devices (RCB/RCD/ELCB/GFCI/ALCI/RCBO), definitions and what to use where
- Lightning strikes and surge protection devices (TVSS/ SPD), how they operate, where to use and how to install
- Power cabling and cable run considerations
- Generators;
- Component make up
- Choosing the required device
- Calculate required fuel storage tank capacity
- Paralleling of gen-sets
- Regulatory requirements
- UPS Systems;
- Required specifications for UPS systems
- How to read data sheets and select the correct UPS
- Requirements for parallel configurations and avoid pitfalls such as single point of failures
- How parallel installation should be done, classic mistakes made by installers and how to avoid these
- Harmonic Filters;
- Type of filters available and which one to select depending on the application
- Battery Banks;
- Designing battery banks, how to calculate, and double check the battery bank to be installed
- Battery charging pitfalls and ensuring the right charger is being installed and used
- Using parallel battery banks; how to properly install them, limitations and risk when using batteries in parallel
- How to test batteries correctly and make decisions on cell/block or string replacement
- Battery casing choices; ABS, V0, V1, V2
- Alternative energy storage; flywheel, re-useable cell etc.
Advanced Electro Magnetic Fields
- Differences between single, three phase and bus-bar EMF
- Options available to measure EMF and how to interpret the results from single axe and composite measurements
- Guidance on safe distance for equipment and human
- Calculation of EMF attenuation factor for shielding material permeability and saturation factors
Advanced Cooling
- Environmental class definitions and thermal specifications
- Equipment airflow and Delta-T definitions and limits
- Planning for floor, rack and cooling equipment
- CFM requirement calculations and conversions
- Air-conditioner specifications and how to select the correct air-conditioner with the required capacity and flow
- Techniques for optimization of air flow
- Redundancy guidelines for air-conditioners avoiding classic misconceptions
- Liquid cooling guidelines for data centres
Cooling Advanced Fire Protection
- Fire triangle and elements to stop a fire
- Detection systems in detail (VESDA, VIEW, Smoke sensors)
- Considerations for installation of sensors
- Difference in water based systems i.e. dry-pipe, pre-action and why most of them don't work and how to detect this
- Details on Inert, Halocarbon, fluorinated systems and how to select the correct gas for your data centre
- How to calculate the gas content ensuring the appropriate level is installed to suppress the fire
- Other requirements for gas systems (release times, hold times, pipe install requirements and other important factors
- Requirements for the fire panel
- Installation verification, what to check and how
- New fire suppression techniques which prevents fires from igniting
Cable Management
- In rack power and network cabling
- Labeling based on TIA-606
Environmental Specifications
- Acoustic noise regulations, specifications, effects and limits
- Data centre contaminations and classifications
- Measurements, standards and limits
- Preventive measures and avoidance
- Electro Static Discharge (ESD)
Data Centre Efficiency
- Power efficiency indicators
- How to measure it and what are acceptable numbers compared to the general industry
- How to achieve power savings in the data centre; various techniques to save energy in all parts of the data centre i.e. application/system level, cooling, power distribution
This is a version-specific reference outline. Confirm the current syllabus and delivery arrangements with EIEIO.